validations:te4-solid-twisted-beam

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
validations:te4-solid-twisted-beam [2023/02/01 07:54]
Ali Baba
validations:te4-solid-twisted-beam [2023/05/31 20:40]
Ali Baba
Line 55: Line 55:
 **The stress values are identical between Abaqus and SesamX**. **The stress values are identical between Abaqus and SesamX**.
  
-As expected, due to identical element formulation the results are the same between the Abaqus C3D4 element and the SesamX TE4 SOLID element.+As expected, due to identical element formulation the results are the same between the Abaqus C3D4 element and the SesamX TE4 SOLID-ISOPARAM element.
  
 ===== Validation data ===== ===== Validation data =====
  
-  * {{ :validations:700_te4_solid_std_beam_3d.inp | Abaqus input file}} +  * {{ :validations:700_te4_solid_isoparam_beam_3d.inp | Abaqus input file}} 
-  * {{ :validations:700_te4_solid_std_beam_3d.sx | SesamX input file}}+  * {{ :validations:700_te4_solid_isoparam_beam_3d.sx | SesamX input file}} 
  
  • validations/te4-solid-twisted-beam.txt
  • Last modified: 2023/05/31 20:40
  • by Ali Baba