validations:te10-solid-twisted-beam

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
validations:te10-solid-twisted-beam [2023/02/01 07:58]
Ali Baba
validations:te10-solid-twisted-beam [2023/05/31 20:36]
Ali Baba [Validation data]
Line 56: Line 56:
 **The stress values are identical between Abaqus and SesamX**. **The stress values are identical between Abaqus and SesamX**.
  
-As expected, due to identical element formulation the results are the same between the Abaqus C3D10 element and the SesamX TE10 SOLID element.+As expected, due to identical element formulation the results are the same between the Abaqus C3D10 element and the SesamX TE10 SOLID-ISOPARAM element.
  
  
 ===== Validation data ===== ===== Validation data =====
  
-  * {{ :validations:703_te10_solid_std_beam_3d.inp | Abaqus input file}} +  * {{ :validations:703_te10_solid_isoparam_beam_3d.inp | Abaqus input file}} 
-  * {{ :validations:703_te10_solid_std_beam_3d.sx | SesamX input file}}+  * {{ :validations:703_te10_solid_isoparam_beam_3d.sx | SesamX input file}}
  
  • validations/te10-solid-twisted-beam.txt
  • Last modified: 2023/05/31 20:40
  • by Ali Baba